SONEX Clean Baffle, Wall Panels, Ceiling Tiles ÀÇ ±â¼úÀÚ·á
Materials
- Made from pinta¡¯s Class 1 fire-rated willtec¢ç melamine foam core
- Fully encapsulated in FR taffeta vinyl
- 17 standard colors
Installation/Size
Ceiling Tiles (24" x 24" x 2¡± or 24" x 48" x 2")
- Drop into any pinta acoustic or standard ceiling grid system

Panels (24" x 48" x 2")
- Attach in seconds to wall and/or ceiling surface with pinta¡¯s acouSTIC water-based adhesive or hook and loop or other mechanical systems

Baffles (24" x 48" x 2")
- Equipped with grommets, easily installed on ceiling-mounted cables or chains
Physical Data - willtec Core
Material Open-cell melamine-based foam
Density 0.5 to 0.7 lbs./cu. ft. (ASTM D3574-77)
Long-Term Service Temperature 302¡ÆF
Fire Resistance Class 1 per ASTM E 84 Meets UL 1715 (willtec natural)
Flame Spread per ASTM E 84 Natural: 5
Smoke Density per ASTM E 84 Natural: 50
Microbial Growth Passes UL 181, section 11
Fungus Resistance Rating 0 per ASTM G21
Physical Data - FR Taffeta Vinyl
Material 4.00 mil PVC film
Flammability Meets California fire marshal requirements
section 13115 CA Health and Safety Code
Sound Absorption
Ceiling Tiles
Test ASTM C423-07; Mounting Type E
Wall Panels
Test ASTM C423-07; Mounting Type A
Baffles
Sabins per Baffle per ASTM C423-07; Hanging Baffle
Frequency (Hz)
2" Thickness
Frequency (Hz)
2" Thickness
Frequency (Hz)
2" Thickness
125
0.57
125
0.18
125
1.88
250
0.67
250
0.75
250
5.23
500
0.91
500
1.21
500
10.33
1000
0.90
1000
0.82
1000
11.84
2000
0.43
2000
0.40
2000
5.33
4000
0.19
4000
0.25
4000
2.99
NRC
0.75
NRC
0.80
NRC
8.20
Color Chart